Insertion Discontinuity
Discontinuous weft insertion defines an interruption across the width of a woven structure where a single filling yarn terminates before reaching the opposite selvedge. A broken pick occurs when tensile failure, package sloughing, or feeder binding severs the linen yarn during traverse through the shed. Rapier grippers or air-jet nozzles lose purchase of the flax strand, which leaves a partial void along that horizontal coordinate.
The automated loom stop motion should halt the beat-up cycle immediately upon detecting the absent yarn tip. When a sensor fails to register the break or an operator resets the machine without drawing out the remnant, the reed packs the partial length firmly against the cloth fell, fixing a permanent transverse flaw into the fabric face.
Inspection Penalty
Grading routines evaluate these insertion faults under standardised illumination against fixed surface inspection protocols such as the four-point fabric evaluation system. The occurrence of a broken pick incurs a point penalty directly proportional to its linear length across the bolt. If the discontinuous strand runs less than three inches before parting, standard criteria typically assess one or two penalty points, whereas breaks extending past nine inches draw the maximum four points per instance.
In pure flax weaves, uneven yarn mass and variable twist can accentuate the optical shadow cast by the missing segment, making the defect conspicuous against the surrounding ground. Inspection sheets record the linear position of each broken pick along with the running roll yardage to calculate aggregate defect densities prior to export release.
Mechanical Cause
Mill floor investigations trace this filling failure to specific points of friction within the yarn delivery path or excessive tension spikes during the insertion cycle. High wet spun linen yarns maintain low elasticity, leaving little room for dynamic shock when the rapier head transfers the yarn at mid-shed. Abrasion against eyelets, unrefined accumulators, dry room humidity levels beneath required moisture equilibria, or slubs jamming within the reed dent wire will break brittle bast fibres cleanly.
Preventative machine maintenance focuses on weft tension settings and accumulator brake rings to ensure smooth unwinding. Proper setting of the electronic weft feeler guarantees that the drive stops before beat-up secures a severed strand.