Tensile Verification
Standardized laboratory tension testing determines the breaking force and elongation at break of individual textile fibres in the conditioned state. Quality control laboratories conduct ISO 5079 testing using single-fibre tensile testing equipment operating at constant rate of extension. Test certificates report mean breaking tenacity expressed in centinewtons per tex alongside coefficient of variation values for raw flax shipments.
The international standard applies exclusively to single fibre specimens, establishing a strict testing boundary that excludes multi-fibre bundles or spun yarn strands.
Methodological Execution
Single fibre specimens are mounted individually across pneumatic clamps using precise gauge lengths under specified pre-tension settings. Laboratories implement ISO 5079 testing across raw flax shipments to verify fibre strength compliance before blending and carding operations begin. The test instrument elongates the fibre specimen until rupture occurs, recording force-elongation curves to calculate tenacity and work of rupture.
Operators test fifty individual fibres per sample lot to achieve statistically valid mean values, noting environmental temperature and relative humidity parameters on formal test records. Flawed mounting or specimen slipping in the jaws invalidates test runs, requiring immediate re-testing under standardized atmospheric conditions.
Acceptance Limit
Dry bast fibres exhibit lower elongation values compared to synthetic staple fibres, requiring delicate handling during specimen loading. Fiber bundles failing minimum tenacity thresholds trigger automatic lot rejections at mill receiving docks. Standardized reporting formats mandate displaying breaking force alongside gauge length specifications.