Clearance Gauge
Calibrated strips of hardened spring steel manufactured to precise imperial or metric thicknesses measure the physical gap width between adjacent mechanical surfaces. Maintenance personnel use a feeler gauge to verify and set mechanical tolerances across flax processing equipment, particularly between carding cylinder wire faces, drawing roller nips and hackling comb passages. The operator inserts individual blades or combined leaves of known thickness into the opening until a smooth sliding friction indicates an exact fit.
Any deviation from the equipment builder specification alters mechanical control over running flax bundles. Gaps set too wide allow uncombed fibres to slip past working zones without parallelisation, whereas excessively tight clearances produce metal-on-metal interference or crush delicate fibres.
Carding Setting
Machine technicians deploy sets of flexible steel leaves during the mechanical overhaul and daily recalibration of tow cards and gill boxes. Carding mechanics slide individual blades between the main drum clothing and the worker or stripper rollers, recording the measured clearances on the carding maintenance log. Mill specifications define clearance profiles across the sequence of carding points, starting wide at entry points to accept raw stricks and tapering toward exit rollers to open dense flax networks.
When mechanical settings drift due to thermal expansion or loose housing bolts, the feeler gauge confirms the precise movement needed to restore the manufacturer tolerance. Measurements rely entirely on operator manual touch, requiring consistent tactile resistance without forcing or bending the thin metal leaf.
Mechanical Scope
Spring steel leaves measure only accessible gaps between rigid parallel structures and cannot assess curved geometries, sealed housings or variable clearances on moving machinery. The blades provide static physical verification during idle maintenance windows, leaving dynamic gap variations caused by high-speed operational loads unmeasured. Dirty surfaces or residual bast wax clinging to wire teeth yield false clearance readings by obstructing blade entry.
Optical comparators and ultrasonic gap sensors replace manual leaves where mechanical housings prevent physical blade insertion. Static clearance verification remains fundamental to avoiding fiber breaking and wire jamming during industrial spinning runs.